MENU
China Chamber of Commerce

Overseas Economic and Trade Zones

Confirm
Cancel
x

Ok
x
Sign into your account
Member ID or Email
Join Free
Water Well Logger Test Self Potential Natural Gamm
Water Well Logger Test Self Potential Natural Gamm

Water Well Logger Test Self Potential Natural Gamm

Member Details

Chongqing Gold M&E Equipment Co., Ltd-Geological

Nananqu,Chongqing,China
  • Product Details
  • Company Profile

Water Well Logger Test Self Potential,Natural Gamma, Resistivity.

 Water Well Logger Test Self Potential Natural Gamma

 

Main Applications and Features

1         Coal Field Digital Integrated Logging

2         Hydrological Engineering Digital Integrated Logging

3         Solid Metal Ore Digital Integrated Logging

4         Other Minerals Digital Integrated Logging

5         External Laptop (Desktop PC)

6         For upward logging, also for downward logging

7         Receive digital signal, analog signal

8         8 taps of power supply current, Optional

9         Automatic sampling as per depth interval, sampling interval arbitrarily

10      Indoor simulation logging, repeatability observation of instruments and probes

11      Membrane panel, attractive and durable.

 

Technical Specifications

1         12bit A/D Conversion, Program-Controlled Magnification K=0.5~128

2         Counting Channel: f≤500KHz

3         Digital Signal Transmission Frequency: 9600bit/s

4         Power Supply Cycle: 400ms

5         Current: 2mA~500 mA Optional

6         Signal Input Range: ≤±10V

7         Continuous Working Time: ≤24 hr

8         Power Consumption: <200W

9         Volume: 420×260×210mm,

10      Weight: <7Kg

11      Working Temperature Range: -10°C~ +50°C

12      Working Power Supply: AC220V±10% 50Hz ±5%

13      Logging Speed: 0~30 m/min Adjustable (as per sampling interval)

Logging Working Software System

1         12bit A/D Conversion, Program-Controlled Magnification

2         ?Operation Environment: Windows98/2000/XP

3         Sampling Interval: Arbitrary (1~1000cm)
Setting (1cm, 2cm, ...1000cm)

4         Maximum depth of one-time acquisition: 3000m (0.1m sampling interval)

5         Depth automatic alignment of multi-parameters

6         Superposition of multi-parameters up to 10

7         Curve movement, anomaly removal, smoothing, inverted order, , segmentation, calculation, etc.

8         Interpretation of profile input, automatic generation of rock stratum name, thickness and baseplate depth

9         Curve amplification and compression

10      5 types of curve depth ratio: 1:50, 1:100, 1:200, 1:500, 1:1000

11      Continuous drawing production in color or black-and-white effects

12      Output graph maximum width: 415mm, length: 2310mm.

Send Inquiry to This Supplier

  • Title
  • From*
  • toVivienne
  • Message*
  • Minimum Order Quantity*
  • Unit
  • Verification Code*